The flake ice machine system is faulty, what should I do?

Author:Dongguan Geally Refrigeration Technology Co., Ltd Date:2022-08-30 Reading:

The flake ice machine system is faulty, what should I do?

The common system failure and overload protection of flake ice machine is due to the accumulation of dust in the condenser, resulting in poor heat dissipation of the condenser and system failure. Only need to clean the condenser, reset the condenser fan overload protection button, cut off the power and then turn on the power, restart the flake ice machine to resume use.

The flake ice machine's phase failure, wrong phase, high pressure and low pressure may cause system failure. How to deal with the flake ice machine system failure? First find out the cause of the system failure.

1. Phase loss: Check whether the incoming power supply of the machine is out of phase, and whether the line is loose, and strengthen the line in time.

Second, the wrong phase: the phase sequence is reversed, just switch any two of the three live wires.

3. The flake ice machine system failure caused by high pressure.

⑴. Check whether the condenser is blocked by debris. Treatment method: Clean the condenser (should be cleaned once a month).

2. Check whether the refrigerant charge is too much. Treatment method: release excess refrigerant.

⑶. Check whether the high pressure pressure controller is damaged. Replace pressure controller.

78eb91da40c04cf11fa751a4390d04a5.jpg

4. The flake ice machine system failure caused by the low-voltage failure.

1. Check whether the refrigeration system is blocked.

2. Check whether the refrigerant in the refrigeration system is missing. Treatment method: add the same type of refrigerant.

3. Check whether the solenoid valve is damaged.

4. Whether the low pressure pressure controller is damaged.

5. Check whether the water supply pump of the system is supplying water normally.

Some of the above content is from the Internet and is for reference only. Jili Refrigeration has been engaged in the production and sales of direct cooling block ice machines, block ice machines, flake ice machines and other equipment for many years.


Share:
主站蜘蛛池模板: 国产精品日韩大片 | 不卡一卡二卡三 | 乱伦高清综合免 | 精品成人免费 | 国产精品国色 | 韩国a级特黄特 | 成人污网 | 成人a大片 | 国产视频一区二区 | 国产91精品系 | 国产精品三级网 | 成人精品人成网站 | 91一区二区视频 | 精品美女| 成人午夜婬片A | 日韩精品亚 | 国产在线不卡播放 | 国产美乳艺术一区 | 欧美做a一级视频 | 成人看片黄在线观看 | 国产精品夜夜春夜夜 | 国产精品秘蜜蕾丝袜 | 国产视频不卡一区 | 国产精品+老牛影视 | 国产免费99热精品 | 欧洲无线一线 | 91成人精品亚洲高 | 国产日韩欧美顶级片 | 国产免费毛卡片 | 国产精品成人国产乱 | 日韩在线最新国产 | 日本不卡不卡 | 国产精品福利 | 91视频www| 乱伦中文 | 日韩午夜福利免 | 91影视网| 欧洲在线观看一区二 | 午夜影视污 | 日本阿v视 | 拍免费视频 |